• AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank
  • AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank
  • AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank
  • AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank
  • AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank
  • AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank

AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank

After-sales Service: 1years
Material: Steel
Warranty: 1 Years
Protection Level: IP23
Voltage: AC400V/230V 3p/1p
Rated Load: 3kw, 3.5kw, 4kw, 4.5kw, 5kw, 6kw, 7kw
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Application
Data Center/UPS
Customized
Customized Available
Surface Treatment
Paint
Frequency
50/60Hz
Load Adjust
MCB(ABB Brand)
Input Source
Single/Dual
Packing
Carton
Certificates
CE/ISO9001/ISO14001/ISO45001
Transport Package
Carton
Specification
Reference the specification following
Trademark
Rata
Origin
China
HS Code
9030899090

Product Description


>Application

3kW,3.5kW,4kW,5kW,6kW,7kW,10.5kW,12kW load bank generally used for IST commissioning in data center & data room. Testing both electrical network (UPS, Diesel generator, etc.) & air conditioning (free cooling, etc.), the rack-mounted load bank is simulating exact electrical & air conditioning impact of servers in the rack cabinet.
 
AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank
Specification - Customized available
Certificates CE/ISO9001:2015/ISO14001:2015/ISO45001:2018/SGS
Product name Rack mounted load bank
Capacity 3kW,3.5kW,4kW,4.5kW,5kW,6kW,7kW,10kW,12kW
Design voltage 400/230VAC,3/1Phase,50/60Hz
Load adjust MCB(ABB brand)
Minumum Load Step 500W/1000W
Input source Single/Dual
Source selection Manual
Fan working source Internal from testing power source
Protection IP23
Duty cycle  Continuous
Operation Panel
Ventilation
Cooling low noises,horizontal forced air cooling AC/DC fans,powered from the test sorce.
Air flow Air sucked in the front and blow out horizontally at the rear
Mechanical characteristics
Technology Expanded metal grids type insulated by ceramic rings
Housing Steel
Height 3kW,3.5kW=3U,4kW,4.5kW=4U,5kW,6kW,7kW=6U
Weight Maximum 30kg
Movement 2 front handles
Element type High temperature ni-chrome finned resistor elements
Accessories
3/6 cables C13/C19/C20 2Mtr
Options 1: High temperature alert
2: Air flow adjustable
3: Dual power source
4: Cable length selection(3m,6m,12m,15m)

> Product Pictures

AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load BankAC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank

> Certificates

AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category

Supplier Homepage Products Rack Mounted Load Bank AC/DC 3p/1p Horizontal Air Cooled MCB Manual/Auto Control IP23 Continuous Duty Cycle Data Center Resistive Rack Mounted Load Bank

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
24
Year of Establishment
2013-09-09