100kVA Resistive Inductive AC Air Cooled Load Bank

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 12 Months
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
24
Year of Establishment
2013-09-09
  • 100kVA Resistive Inductive AC Air Cooled Load Bank
  • 100kVA Resistive Inductive AC Air Cooled Load Bank
  • 100kVA Resistive Inductive AC Air Cooled Load Bank
  • 100kVA Resistive Inductive AC Air Cooled Load Bank
  • 100kVA Resistive Inductive AC Air Cooled Load Bank
  • 100kVA Resistive Inductive AC Air Cooled Load Bank
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • Customers Visitation
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
RT100KVALB
Type
Generator Load Testing
Test Region
Charge and Discharge
Application
Load Testing
Customized
Customized
Name
100kVA Load Bank
Usage
Generator Load Testing
Control Mode
Local Panel Control and Automatic Control
Color
Ral7035/Customized Available
Design
Indoor Design
Movement
Universal Wheels
Certificates
CE, ISO9001, ISO14001, ISO45001
Packing
Wooden Pallet+Wooden Case
Service 1
Techinical Meeting Online Before Order
Service 2
Help You to Discuss Your Solutions& Solve Problems
Service 3
Customized Price According to Your Budget
Service 4
Video/Picture Following for Manufacturing
Service 5
Quick Response for Datasheet &Diagrams, Problems
Service 6
Video or Online Inspection of The Testing Process
Frequency
50 or 60Hz
Transport Package
Wooden Pallet+ Wooden Case
Specification
100KVA
Trademark
Rata
Origin
China
HS Code
9030899090
Production Capacity
10 Sets/Months

Product Description

100kVA Resistive Inductive AC Air Cooled Load Bank

HS Code:9030899090
Certificates: CE,ISO9001,ISO14001,ISO45001 
OEM,ODM available
 
Product Description

100KVA Resistive Inductive AC Air Cooled Load Bank with local panel control. Indoor design(outdoor design is available).Generally used for generator load testing. 

Product Parameters
Load bank Series No. RT100KVALB
Formation Resistive load,inductive load,data acquisition,electrical control part,heat dissipation device and load protection control
Test voltage Based on customer's needs,such as AC400V,440V,450V,480V,690V,10.5KV,etc.
Test frequency 50Hz/60Hz
Load character Resistive load + Inductive load
Load power 100kVA
Power factor 0.8
Power source connection Copper bar + Terminal  3phase,3/4 wire
Loading accuracy  ±3%
Three phase balance Inbalance: ≤ 3%
Working mode Continuous work
Cooling mode Forced air cooling,horizontal air discharge
Insulation class F
Accuracy The sampling accuracy of the instrument is 0.2;
(Voltage:±0.5%,current:±0.5%,frequency:±0.1%,power:±1%,Cos:±1% )
Load expansion Parallel expansion of multiple load containers
Load protection Short circuit, over voltage, over current, high temperature, air volume, emergency stop protection
Resistive
 load
Minimum step 1kW
Load step According to customer needs
Resistance tube Insulation impedance of each resistance element DC1000V 20M Ω above,
withstand voltage AC2000V 1 minute,
Resistance error of each resistance tube:±3%
Resistive material 8020 Ni-Cr alloy resistor
Cold and hot state change ≤ 2%
Inductive load Minimum step 1kvar
Load step According to customer needs
Inductor Withstand voltage AC3000V 1 minute,
inductance error of each Inductor:±3%
Material Copper reactor
Other Protection level IP23
Use occasion Indoor design
Transport Universal wheels 
Color RAL7035 or customized
Standard Meet international standard, ship standard and telecommunication standard
Color Customized
Ambient temperature -20ºC to 50ºC
Humidity Up to 100%
Altitude Up to 2500m
Atmospheric pressure 86 to 106kPa
 
Detailed Photos
100kVA Resistive Inductive AC Air Cooled Load Bank100kVA Resistive Inductive AC Air Cooled Load Bank100kVA Resistive Inductive AC Air Cooled Load Bank100kVA Resistive Inductive AC Air Cooled Load Bank100kVA Resistive Inductive AC Air Cooled Load Bank100kVA Resistive Inductive AC Air Cooled Load Bank
 
Company Profile

Rata was established in 2013 and located at Luojiang High and New Technology Zone, Deyang City, China. The factory is nearby the high way and national road, with convenient shipment. It is about 5 hours from our factory to the nearest port. There are professional technicians and skilled workers. During past 10 years, we are focus on development and production of kinds of load bank. By far, we have obtained 25 patents of load bank, ISO 9001/14001/45001 certificates,SGS factory inspection,CE certificate and 8 computer software copyrights. We are not only focus on products quality, but also on service. By far we obtained 5 stars contract performance capacity certificate and 7 stars after sales service certificate. Rata Technology mainly produce and sale resistive load bank, resistive reactive load

bank, rack mounted load bank, DC load bank, electrical load bank and battery discharger. Our load bank have been exported to America,Europe, Africa, Asia and other regions and have good reputation. You are welcome to visit our factory and look forward to cooperate with you.
100kVA Resistive Inductive AC Air Cooled Load Bank100kVA Resistive Inductive AC Air Cooled Load Bank100kVA Resistive Inductive AC Air Cooled Load Bank
Customers Visitation

100kVA Resistive Inductive AC Air Cooled Load Bank

 
Certifications

We obtained CE,ISO9001,ISO14001,ISO45001 certificates.

FAQ

 

1:What is the HS code?
9030899090

2:What is the language of the operation instruction?
Generally the language will be English,but it can be your local language based on your help to translate it.

3:What is the language of the operation panel and control software?
Generally the language will be English,but it can be your local language based on your help to translate it.

4: What is the guarantee time?
Generally12 months start from commissioning on site.

5: Can you supply Certificate of Original?
Yes.

6: .What are the brands for the components?
Contactor: ABB/Schneider,Breaker: ABB/Schneider,Fuse: Delixi,PLC: Siemens,Fan: Fengmai,Resistor: Zhuxing all are first level brand at international and China market.

7: What is the noise? 
Actually noise:≤80dB(1m) 

100kVA Resistive Inductive AC Air Cooled Load Bank   
8:Do you support OEM?
Yes.

9:Do you support customized control software?
Yes.

10:What is the after sales service time?
We supply 7×24hrs after sales service.But maybe there is some delay caused by the time zone restrictions.

11:Who should we contact for the after sales service?
You may contact the salesman for the after sales service directly caused by the language restrictions.

12:What is the delivery time?
The delivery time based on the power capacity and quantity.

13:How to operate the load bank as "local-off-remote"?
There is indication for "local"and"remote" control on the local panel.And it is controlled by key. Turn the key to "local" direction,then can control the load bank manually;turn the key to "remote",then can control the load bank remotely.

14:Does it complicated to use the remote control software?
It is say to use the control software,we can supply the operation video for your reference.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier