Resistive Load Bank for Generator Load Testing

Product Details
Customization: Available
After-sales Service: 12 Months
Material: Q235 Steel
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
24
Year of Establishment
2013-09-09
  • Resistive Load Bank for Generator Load Testing
  • Resistive Load Bank for Generator Load Testing
  • Resistive Load Bank for Generator Load Testing
  • Resistive Load Bank for Generator Load Testing
  • Resistive Load Bank for Generator Load Testing
  • Resistive Load Bank for Generator Load Testing
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Warranty
12 Months
Protection Level
IP23
Voltage
400V/Customized
Rated Load
100kw
Application
Load Testing
Customized
Customized
Surface Treatment
Powder Coating
Name
100kw Load Bank
Usage
Generator Load Testing
Control Mode
Local Panel
Color
Ral7035/Customized Available
Design
Indoor Design
Movement
Universal Wheels
Certificates
CE, ISO9001, ISO14001, ISO45001
Transport Package
Wooden Pallet+ Wooden Case
Specification
100kW
Trademark
Rata
Origin
China
HS Code
9030899090
Production Capacity
5 Sets/Months

Packaging & Delivery

Package Size
70.00cm * 50.00cm * 96.00cm
Package Gross Weight
100.000kg

Product Description

Resistive Load Bank for Generator Load Testing

HS Code:9030899090
Certificates: CE,ISO9001,ISO14001,ISO45001 
OEM,ODM available
 
Product Description

100kW resistive load bank with local panel control(automatic control available).Indoor design(outdoor design is available).Generally used for generator load testing. 

Product Parameters
100kW Resistive Load Bank Data Sheet
Model No. RT100KVALB
Load type Resistive 
Tested power 400VAC(customized available),3P4W,connected with copper bar
Work power 220~240VAC,1P2W,connected with terminal(fast connector is available)
Frequency 50 or 60Hz
Capacity 100kW
Power factor 1.0
Load accuracy ±3%
3Phase balance Unbalance: ≤3%
Insulation F
Protection level IP23
Time rating Continuous design
Control mode Local panel manual control (remote PC automatic control is available)
Design Indoor design
Resistive load Min.step: nominal 1kw resolution or customized
Steps: 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,customized steps are available.
8020 NiCr alloy finned resistor
Cooling system Forced air cooling,horizontal air inlet/outlet with AC fan,noise≤85dB(1m)
Functions Real time display of current/voltage/power/power factor/frequency
Load protection/ function Low air volume/high temperature/short circuit/over current/emergency stop/operational indicator/fan operation indicator/load switch
Enclosure RAL7035 or customized/Q235 cold rolled steel plate.
Transportation Universal wheels 
Dimension 700×500×960mm
Weight 100kg
Packing Wrapping film+wooden pallet+wooden case
Temperature -20ºC to 50ºC
Humidity up to 100%
Altitude up to 4000m
Atmospheric pressure 86 to 106kPa
Detailed Photos

100kW load bank photos(indoor design) for reference.

Resistive Load Bank for Generator Load TestingResistive Load Bank for Generator Load TestingResistive Load Bank for Generator Load TestingResistive Load Bank for Generator Load TestingResistive Load Bank for Generator Load TestingResistive Load Bank for Generator Load Testing

Company Profile

> Established in 2013
> 1600 square meters production shop
> 120 square meters office
> 22 employees
> 25 patents for load bank
> 10 years load bank design,production,service experience
> 8 computer software copyrights
> 7 stars after sales service certificate

> ISO9001:2015,ISO14001:2015,ISO45001:2018,CE certificates
> Clients come from include but not limited: South Korea,India,Kazakhstan,Indonesia,UAE,Denmark,France,Rwanda,New Zealand,Chile,Paris,Peru,America..

Resistive Load Bank for Generator Load Testing

> Load Bank Factory Test

Resistive Load Bank for Generator Load Testing
> Clients Visitation

Resistive Load Bank for Generator Load Testing
> Certificates(CE,ISO9001,ISO14001,ISO45001)

Resistive Load Bank for Generator Load Testing
FAQ

1:What is the HS code?
9030899090

2:What is the language of the operation instruction?
Generally the language will be English,but it can be your local language based on your help to translate it.

3:What is the language of the operation panel and control software?
Generally the language will be English,but it can be your local language based on your help to translate it.

4: What is the guarantee time?
Generally12 months start from commissioning on site.

5: Can you supply Certificate of Original?
Yes.

6: .What are the brands for the components?
Contactor: ABB/Schneider,Breaker: ABB/Schneider,Fuse: Delixi,PLC: Siemens,Fan: Fengmai,Resistor: Zhuxing all are first level brand at international and China market.

7: What is the noise? 
Actually noise:≤80dB(1m) 

8:Do you support OEM?
Yes.

9:Do you support customized control software?
Yes.

10:What is the after sales service time?
We supply 7×24hrs after sales service.But maybe there is some delay caused by the time zone restrictions.

11:Who should we contact for the after sales service?
You may contact the salesman for the after sales service directly caused by the language restrictions.

12:What is the delivery time?
The delivery time based on the power capacity and quantity.

13:How to operate the load bank as "local-off-remote"?
There is indication for "local"and"remote" control on the local panel.And it is controlled by key. Turn the key to "local" direction,then can control the load bank manually;turn the key to "remote",then can control the load bank remotely.

14:Does it complicated to use the remote control software?
It is say to use the control software,we can supply the operation video for your reference.

Resistive Load Bank for Generator Load Testing

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier