2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank

Product Details
Customization: Available
After-sales Service: 12 Months
Material: Q235 Steel
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
24
Year of Establishment
2013-09-09
  • 2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
  • 2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
  • 2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
  • 2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
  • 2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
  • 2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
RT2000KWLB
Type
Resistive Load Bank
Structure
Container Type
Warranty
1 Year
Protection Level
IP55
Voltage
440V/380V
Rated Load
2680kw
Application
Generator Testing
Customized
Customized
Surface Treatment
Powder Coating
After Sales Service
7*24 Hours
Quality Assurance
12 Months Start From Your Commissioning
Certificates
ISO9001/ISO14001/ISO45001/CE/SGS
Packing
Wrapping Film+Wooden Pallet
Design
Container Type
Control
Local Panel + Remote PC Control Mode
Rated Voltage
440V/380V
Load Steps
Customized
Cooling
Horizontal Air Inlet/Vertical Air Outlet
Fan
Axial Fan
Transport Package
Wrapping Film
Specification
4500*2438*2593mm
Trademark
Rata
Origin
China
HS Code
9030899090
Production Capacity
3 Set/Month

Product Description

2MW(380V)/2680kW(440V) AC Air Cooling Resistive Load Bank

HS CODE: 9030899090
Certificates: ISO9001:2015/ISO14001:2015/ISO45001:2018/CE

 
Product Parameters
2MW/2680kW Resistive Load Bank Data Sheet
Model No. RT2680KWLB
Load type 100% Resistive
Tested power 440/380VAC(customized available),3P4W,connected with copper bar
Work power 380VAC,3P4W,connected with terminal
Frequency 50Hz
Capacity 2680kW
Power factor 1.0 
Load accuracy ±3%
3Phase balance Unbalance: ≤3%
Insulation F
Time rating Continuous design
Control mode Manual control + Remote PC control
Design Container type
Resistive load Steps: based on 380V: 10kW+20kW+30kW+40kW+100kW+100kW+100kW+100kW+500kW+500kW+500kW
8020 NiCr alloy finned resistor
Cooling system Forced air cooling,horizontal air inlet/vertical air outlet
Functions Real time display of current/voltage/power/power factor/frequency
Load protection/ function Low air volume/high temperature/fan interlock protection/short circuit/over
current/emergency stop/fan phase sequence automatic transfer protection/
operational indicator/fan operation indicator/load switch
Enclosure RAL7035 or customized/Q235 cold rolled steel plate.
Transportation Lifting points
Dimension 4500mm*2438mm*2593mm
Weight 6500kg
Packing Wrapping film
Temperature -20ºC to 50ºC
Humidity up to 100%
Altitude up to 4000m
Atmospheric pressure 86 to 106kPa

 

 

Detailed Photos


2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
Vertical air outlet - Air duct
2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
Remote control - computer with operation software
2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank

Company Profile

> Established in 2013
> 1600 square meters production shop
> 120 square meters office
> 22 employees
> 25 patents for load bank
> 10 years load bank design,production,service experience
> 8 computer software copyrights
> 7 stars after sales service certificate

> ISO9001:2015,ISO14001:2015,ISO45001:2018,CE certificates
> Clients come from include but not limited: South Korea,India,Kazakhstan,Indonesia,UAE,Denmark,France,Rwanda,New Zealand,Chile,Paris,Peru,America..

2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank

> DESIGN
Rata has professional technical team,they have 3~15 years load bank design experience, capable to design low and medium voltage and 2kW~10000kW,5kVA~7000kVA single load bank. We can design the load bank as per customers' reuquirement and based on related standards.
> PRODUCTION
Rata has professional technical team and skilled workers, all the production workers has 1-10 years load bank production experience. All the products produced based on the technical drawings,related standard(ISO9001),production /test/metering equipment(35 types).

> FACTORY TEST/ONSITE SERVICE
All rata produced products will be tested based on related standards,rules and process before delivery. Test report and video will be supplied to customer. Rata also supply charged onsite service include onsite commissioning and training.
2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank

> QUALITY CONTROL
In the design, production, and inspection process of the system, the seller takes the following measures to ensure that the system quality is qualified and can meet the needs of users:
> The design and production of the system are entirely based on the technical agreement agreed upon by both parties.
> Before production, provide the equipment outline drawing to the user, and after confirmation and approval, production can be carried out based on the drawing.
> During the production process, a specialized inspection department conducts strict quality inspections of the raw materials used in the system.
> Conduct full process quality tracking during component processing, assembly, and debugging, and establish product archives.
> Ensure that all accessories are advanced, brand new, complete, and reasonably arranged, in accordance with relevant national standards. The interior of the equipment is clean, the wiring is neat, all wiring conforms to the drawings, and the interfaces and switches are correctly and clearly marked.
> Strictly follow the requirements of the drawings, relevant standards, and specifications to verify the functionality and parameters of the system, ensuring that the final product can achieve all the agreed content in the technical agreement.

> AFTER SALES SERVICE
Rata supply 7×24 hours after sales service. Rata promises to provide lifelong technical services, including the following:
> The system quality assurance period is calculated from the date of system acceptance and lasts for 12 months.
> Rata shall provide free maintenance for any quality issues that arise within the warranty period of the system.
> After encountering problems, users are guaranteed to respond within 2-8 hours based on the time difference.
> If it is necessary to dispatch technical personnel to the site to solve the problem, Rata shall ensure that they arrive at the site within 24-72 hours. Service personnel shall not evacuate until the problem is resolved.
> Users can permanently enjoy free technical consulting services.
> Save complete product technical archives for users.
> After the end of the 12 months warranty period, we provide users with lifelong paid maintenance services at a cost only.
> The supplier is required to provide a cost price list of conventional spare parts, such as resistors and contactors.
> If necessary, the seller will provide users with the most favorable price for system upgrades and renovations.

> CERTIFICATES
We supply ISO9001:2015,ISO14001:2015,ISO45001:2018 and CE certificates. If need other certificates,let me know.

2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
> CUSTOMER VISITATION
You are warmly welcome to visit us,I will go to Mianyang/Chengdu Airport to pic you up and arrange following thing to make sure you will have a happy trip and have a comprehensive understanding of our company.
2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank> LOAD BANK APPLICATION
Load bank generally used for generator,genset,transformer,UPS,shipyard,power plant and others.
2MW (380V) /2680kw (440V) AC Air Cooling Resistive Load Bank
FAQ

1:What is the HS code?
9030899090

2:What is the language of the operation instruction?
Generally the language will be English,but it can be your local language based on your help to translate it.

3:What is the language of the operation panel and control software?
Generally the language will be English,but it can be your local language based on your help to translate it.

4: What is the guarantee time?
Generally12 months start from commissioning on site.

5: Can you supply Certificate of Original?
Yes.

6: .What are the brands for the components?
Contactor: ABB/Schneider,Breaker: ABB/Schneider,Fuse: Delixi,PLC: Siemens,Fan: Fengmai,Resistor: Zhuxing all are first level brand at international and China market.

7: What is the noise?
Actually noise:≤80dB(1m)

   
8:Do you support OEM?
Yes.

9:Do you support customized control software?
Yes.

10:What is the after sales service time?
We supply 7×24hrs after sales service.But maybe there is some delay caused by the time zone restrictions.

11:Who should we contact for the after sales service?
You may contact the salesman for the after sales service directly caused by the language restrictions.

12:What is the delivery time?
The delivery time based on the power capacity and quantity.

13:How to operate the load bank as "local-off-remote"?
There is indication for "local"and"remote" control on the local panel.And it is controlled by key. Turn the key to "local" direction,then can control the load bank manually;turn the key to "remote",then can control the load bank remotely.

14:Does it complicated to use the remote control software?
It is say to use the control software,we can supply the operation video for your reference.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier