3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet

Product Details
Customization: Available
After-sales Service: Yes
Material: Q235 Cold Steel Sheet
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
24
Year of Establishment
2013-09-09
  • 3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet
  • 3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet
  • 3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet
  • 3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet
Find Similar Products
  • Overview
  • Product Parameters
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
RT3125KVALB
Type
Resistive+Inductive
Structure
Non-Standard Container Type
Warranty
12 Months From Commissioning
Protection Level
out Door Design
Voltage
AC400V/690V/6.3kv/10.5kv/Customized
Rated Load
3125kVA/Customized
Application
Generator, Genset, UPS
Customized
Customized
Surface Treatment
Spacial Paint for Ship
Name
Resistive Inductive Load Bank
Insulation
F
Control
Local Panel + Remote PC Control
Protection
Low Air Flow, High Temperature, Emergency Stop
Transport Package
Wrapping Film
Specification
3125kVA
Trademark
Rata
Origin
China
HS Code
9030899090
Production Capacity
15 Sets/Year

Product Description

3125kVA/2500kW/2000kvar Resistor Inductive Generator Load Testing Load Bank
 
HS CODE: 9030899090
Certificates: ISO9001:2015/ISO14001:2015/ISO45001:2018/CE


You are warmly welcome to visit us!

3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet
Product Parameters

Load Bank Specification(Following is 3125kVA load bank main data sheet for reference,contact us for details)

 
Load bank Series No. RT3125KVALB
Formation Outdoor non-standard container type,resistive load,inductive load,data acquisition,electrical control part,heat dissipation device and load protection control
Test voltage Based on customer's needs,such as AC400V,440V,450V,480V,690V,10.5KV,etc.
Test frequency 50Hz/60Hz
Load character Resistive load + Inductive load
Load power 3125kVA,2500kW,2000kvar
Power factor 0.8
Power source connection Copper bar + Terminal  3phase,4 wire
Control mode Local panel manual + remote PC control(support load data save and printing with accommissioning soft ware that will be sent to you)
Loading accuracy  ±3%
Three phase balance Inbalance: ≤ 3%
Working mode Continuous work
Cooling mode Forced air cooling,horizontal air inlet/vertical air outlet
Insulation class F
Accuracy The sampling accuracy of the instrument is 0.2;
(Voltage:±0.5%,current:±0.5%,frequency:±0.1%,power:±1%,Cos:±1% )
Load expansion Parallel expansion of multiple load containers
Load protection Short circuit, over voltage, over current, high temperature, air volume, emergency stop protection
Resistive
 load
Minimum step 1kW
Load step According to customer needs
Resistance tube Insulation impedance of each resistance element DC1000V 20M Ω above,
withstand voltage AC2000V 1 minute,
Resistance error of each resistance tube:±3%
Resistive material 8020 Ni-Cr alloy resistor
Cold and hot state change ≤ 2%
Inductive load Minimum step 1kvar
Load step According to customer needs
Inductor Withstand voltage AC3000V 1 minute,
inductance error of each Inductor:±3%
Material Copper reactor
Other Protection level IP54 when not in use, IP20 when in use
Use occasion Outdoors
Transport Hoisting,lift lug in the top of the casing
Color RAL7035 or customized
Standard Meet international standard, ship standard and telecommunication standard
Color Customized
Ambient temperature -20ºC to 50ºC
Humidity Up to 100%
Altitude Up to 2500m
Atmospheric pressure 86 to 106kPa
 
Detailed Photos

3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet

Company Profile

> Established in 2013
> 1600 square meters production shop
> 120 square meters office
> 22 employees
> 25 patents for load bank
> 10 years load bank design,production,service experience
> 8 computer software copyrights
> 7 stars after sales service certificate

> ISO9001:2015,ISO14001:2015,ISO45001:2018,CE certificates
> Clients come from include but not limited: South Korea,India,Kazakhstan,Indonesia,UAE,Denmark,France,Rwanda,New Zealand,Chile,Paris,Peru,America..

3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet

> DESIGN
Rata has professional technical team,they have 3~15 years load bank design experience, capable to design low and medium voltage and 2kW~10000kW,5kVA~7000kVA single load bank. We can design the load bank as per customers' reuquirement and based on related standards.

> PRODUCTION
Rata has professional technical team and skilled workers, all the production workers has 1-10 years load bank production experience. All the products produced based on the technical drawings,related standard(ISO9001),production /test/metering equipment(35 types).


> FACTORY TEST/ONSITE SERVICE
All rata produced products will be tested based on related standards,rules and process before delivery. Test report and video will be supplied to customer. Rata also supply charged onsite service include onsite commissioning and training.


3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet
> QUALITY CONTROL
In the design, production, and inspection process of the system, the seller takes the following measures to ensure that the system quality is qualified and can meet the needs of users:
> The design and production of the system are entirely based on the technical agreement agreed upon by both parties.
> Before production, provide the equipment outline drawing to the user, and after confirmation and approval, production can be carried out based on the drawing.
> During the production process, a specialized inspection department conducts strict quality inspections of the raw materials used in the system.
> Conduct full process quality tracking during component processing, assembly, and debugging, and establish product archives.
> Ensure that all accessories are advanced, brand new, complete, and reasonably arranged, in accordance with relevant national standards. The interior of the equipment is clean, the wiring is neat, all wiring conforms to the drawings, and the interfaces and switches are correctly and clearly marked.
> Strictly follow the requirements of the drawings, relevant standards, and specifications to verify the functionality and parameters of the system, ensuring that the final product can achieve all the agreed content in the technical agreement.


> AFTER SALES SERVICE
Rata supply 7×24 hours after sales service. Rata promises to provide lifelong technical services, including the following:
> The system quality assurance period is calculated from the date of system acceptance and lasts for 12 months.
> Rata shall provide free maintenance for any quality issues that arise within the warranty period of the system.
> After encountering problems, users are guaranteed to respond within 2-8 hours based on the time difference.
> If it is necessary to dispatch technical personnel to the site to solve the problem, Rata shall ensure that they arrive at the site within 24-72 hours. Service personnel shall not evacuate until the problem is resolved.
> Users can permanently enjoy free technical consulting services.
> Save complete product technical archives for users.
> After the end of the 12 months warranty period, we provide users with lifelong paid maintenance services at a cost only.
> The supplier is required to provide a cost price list of conventional spare parts, such as resistors and contactors.
> If necessary, the seller will provide users with the most favorable price for system upgrades and renovations.


> CERTIFICATES
We supply ISO9001:2015,ISO14001:2015,ISO45001:2018 and CE certificates. If need other certificates,let me know.

3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet
> CUSTOMER VISITATION
You are warmly welcome to visit us,I will go to Mianyang/Chengdu Airport to pic you up and arrange following thing to make sure you will have a happy trip and have a comprehensive understanding of our company.

3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet
FAQ

1:What is the HS code?
9030899090

2:What is the language of the operation instruction?
Generally the language will be English,but it can be your local language based on your help to translate it.

3:What is the language of the operation panel and control software?
Generally the language will be English,but it can be your local language based on your help to translate it.

4: What is the guarantee time?
Generally12 months start from commissioning on site.

5: Can you supply Certificate of Original?
Yes.

6: .What are the brands for the components?
Fuse: Delixi,PLC: Siemens,Fan: Fengmai,Resistor: Zhuxing all are first level brand at international and China market.

7: What is the noise?
Actually noise:≤80dB(1m)

3125kVA/2500kw/2000kvar Resistor Inductive Generator Load Testing Load Bank Project Box for Power Distribution Genset Control Cabinet   
8:Do you support OEM?
Yes.

9:Do you support customized control software?
Yes.

10:What is the after sales service time?
We supply 7×24hrs after sales service.But maybe there is some delay caused by the time zone restrictions.

11:Who should we contact for the after sales service?
You may contact the salesman for the after sales service directly caused by the language restrictions.

12:What is the delivery time?
The delivery time based on the power capacity and quantity.

13:How to operate the load bank as "local-off-remote"?
There is indication for "local"and"remote" control on the local panel.And it is controlled by key. Turn the key to "local" direction,then can control the load bank manually;turn the key to "remote",then can control the load bank remotely.

14:Does it complicated to use the remote control software?
It is say to use the control software,we can supply the operation video for your reference.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier